POLTAVA FOUNDRY AND MECHANICAL PLANT

Pumps for pure (technical) water of the CW series.

For pumping clean water, the specialists of PE "PFMP" developed pumps of the CW (clean water) type - clean water.

Our pumps are an alternative to single-stage overhung pumps and D-type double-bearing pumps (former VAT/NDV). The hydraulic end of CW pumps is made of ductile iron (ductile iron).

Pump name

Assembly diagramPump Rating at Optimum PointMaximum indicators
(not performed simultaneously)
Pump weight (kg)

Feed/Head
(m3/h)/(m)

Speed (min-1)

Power consumption (kW)

Feed (m3/h)

Pressure
(m)

Speed (min-1)

Power consumption (kW)

4/3CW-(1L)-260R-40-PET  AL  100/20 1500  160  59 2200 33 320
6/4CW-(1)-325R-50-PET  200/38 1500  28  400  56 1500 55 450
6/4CW-(2)-400R-55-PET  200/55 1500  43  400  94 2000 110 655
8/6CW-(4)-600R-100-PET  400/62 1000  80  600  89 1200 200 1670
9/6CW-(4)-600R-100-РЕТ 600/60 1000 110 800  91 1200 250 1620
10/8CW-(6)-700R-155-PET  CL 800/55 750  180  1200  81 1000 315 2770
12/10CW-(6)-750R-150-РЕТ 1500/70 750 330 2000  106 1000 500 2870
14/12CW-(7)-900R-130-PET 2000/48 600  300  2500  101 750  800  5050 
16/14CW-(7)-900R-230-PET 3000/46 600  440  4000  78 750  1250  4950 
18/16CW-(7)-950R-260-РЕТ 5000/28 500 420 6000  52 600 800 5250
22/22CW-(7)-1050R-300-РЕТ 7000/39 500 830 10000 65 750 1600 5800

 *For pumps of the CW series, the assembly schemes of the working body A and C are used in a lightweight version without an armored disc (marked AL and CL, respectively). The designation of the pump is not indicated.

 

Pumps for dirty water of the DW series (fecal).

Using the experience of producing soil pumps, we have introduced a line of fecal pumps of the D.W.

Ductile iron ductile graphite (ductile iron) fecal pumps are more wear resistant than MC pumps and certainly cheaper than imported.

Pump name

Assembly diagramPump Rating at Optimum PointMaximum indicators
(not performed simultaneously)
Pump weight (kg)

Feed/Head
(m3/h)/(m)

Speed (min-1)

Power consumption (kW)

Feed (m3/h)

Pressure
(m)

Speed (min-1)

Power consumption (kW)

4/3DW-(1L)-260R-40-PET AL  100/19 1500  160  57  2200 33 320
6/4DW-(1)-325R-50-PET  200/37 1500  28  400  54  1500 55 450
6/4DW-(2)-400R-55-PET  200/53 1500  43  400  93  2000 110 655
8/6DW-(4)-600R-100-PET  400/60 1000  80  600  88  1200 200 1670
9/6DW-(4)-600R-100-РЕТ 600/58 1000 110 800  88  1200 250 1620
10/8DW-(6)-700R-155-PET CL 800/54 750  180  1200  78  1000 315 2770
12/10DW-(6)-750R-150-РЕТ 1500/68 750 330 2000  103  1000 500 2870
14/12DW-(7)-950R-130-PET 2000/47 600  300  2500  99  750  800  5050 
16/14DW-(7)-950R-230-PET 3000/45 600  440  4000  76  750  1250  4950 
18/16DW-(7)-950R-260-РЕТ 5000/27 500 420 6000  50  600 800 5250
22/22DW-(7)-1050R-300-РЕТ 7000/37 500 830 10000 62  750 1600 5800

 *For pumps of the DW series, the assembly schemes of the working body A and C are used in a lightweight version without an armor plate (marked AL and CL, respectively). The designation of the pump is not indicated.

 

sheme AL sheme CL

Explanation of pump names

shl9pa                                                                                                

1. Suction nozzle diameter in inches (from 2" to 28")(36");
2. Discharge pipe diameter in inches (from 1.5" to 24")(32");
3. Pump series (1 - 2 letters). Several series of pumps are produced, different in terms of the geometry of the flow path, depending on the work that the pump has to perform:


- W, WK – high-pressure universal pumps;
- MV – medium head pumps with maximum efficiency, for operation at the OF;
- HG – pumps for large volumes of pumping;
- GR – the same, with the possibility of pumping maximum fractions;
- LG – high-speed, for large volumes of liquid pulp pumping, most suitable for tailing facilities of mining and processing plants;
- CW, DW – clear water / dirty water - pumps for clean or waste water with a simplified design of working bodies;


4. Working body assembly scheme - A, B, C, D:

Scheme A - Single case, single disc
With a single (solid) part (housing / suction disk / suction pipe). Simple, cheap and maintainable design. Suitable for small pumps (2"-4") as well as 5"-9" pumps operating in relatively light conditions.

Scheme B - One and a half body
Best of all are suitable for installation on stationary workplaces (OF, ZIF, TsOF) in severe conditions. They combine excellent wear resistance with a moderate price for spare parts. Available in sizes 5"-14".

Scheme C - Single case, double disc
They are used to work in difficult and especially difficult conditions, with various fractions and unstable conditions. Available in 10"-20" sizes.

Scheme D - Double-case, double-disk
Used in pumps 20", 28", 30".


5. Size and construction of the rack - numbers and letters. Letters may be missing if the design of the rack is standard - cast on liquid lubricant:

- digits from 0 to 11 – rack standard size;

- letters:

- L – light version on a welded frame;

- S - solid grease;

- V – vertical execution;

* Maximum allowable revolutions and loads for each specific rack.

 

6. Diameter of the working wheel in mm and direction of rotation:

- diameter from 240 to 1890 mm;
- R or L - direction of rotation.

 

7. The width of the flow in the working wheel in mm (from 25 to 350 mm).

 

8. Conventional designation of the manufacturer.

 

EXAMPLE: 4/3СW-(1L)-260R-40-PET- a pump for clean (technical) water, with a diameter of 4/3 inch suction / pressure nozzles, on a light version stand No. 1 with an impeller Ø 260 mm of right rotation, with a working chamber width of 40 mm, manufactured by PET.


EXAMPLE: 16/14DW-(7)-900R-230-PET- 
Dirty Water Pump (Sewage), 16/14" Suction/Discharge Ports, No. working chamber 230 mm, produced by PET.

 

 